Running the Simulation
You run the steady simulation for 6000 iterations.
In Eulerian Multiphase simulations, reducing the AMG Linear Solver tolerance and lowering the under-relaxation factors aids solution convergence. In this simulation, you set the convergence tolerance to 0.001 for the Segregated EMP Flow and Volume Fraction solvers.
To run the simulation:
-
Edit the Solvers node and set the following properties:
Node Property Setting Implicit Under-Relaxation Factor 0.3 Explicit Under-Relaxation Factor 1.0
AMG Linear SolverConvergence Tolerance 0.001 Under-Relaxation Factor 0.1
AMG Linear
SolverConvergence Tolerance 0.001 Volume Fraction Implicit Under-Relaxation Factor 0.1 Explicit Under-Relaxation Factor 1.0
AMG Linear
SolverConvergence Tolerance 0.001 - Select the node and set Maximum Steps to 6000.
-
Click
(Run)
in the Solution toolbar.
- When the simulation has finished running, save it.